NOV 80T-3

NOV 80T-3

The NOV 80T-3 product line is one of our continuous and intermittent-duty reciprocating pump lines. With plunger sizes ranging from 1.250” to 3.250”. The maximum displacement pressure for the NOV 80T-3 is between 764 psi (5266 kPA) and 5161 psi (35584 kPA) depending on plunger size.

The NOV 80T-3 products will pump up to 161.6 GPM, or 5,541 BPD at peak performance. The NOV 80T-3 operates in low-to-high pressure applications and offers 24/7 continuous duty run time, resulting in reduced downtime and savings for your overall operational costs. The NOV 80T-3 works in a variety of fluids and offers a variety of fluid end metallurgies.

image_-_2023-12-15T081055.544

Recommended Application Types

  • Fresh Water
  • Salt Water
  • Crude Oil
  • Natrual Gas
  • Propane
  • TEG / Glycol
  • Butane
  • Condensate
PumpEnglish Units200 RPM300 RPM350 RPM400 RPM450 RPM500 RPM
Plunger Dia. In.Plunger Area Sq. in.BPD per RPMGPM per RPMMax Press. PSIBPDGPMBPDGPMBPDGPMBPDGPMBPDGPMBPDGPM
80T-3L3.2508.295811.08150.3232764221764.63325973879113.14433129.34987145.45541161.6
3.0007.06869.44230.2754896188955.1283382.6330596.43777110.24250123.94722137.7
2.7505.93967.93410.23141067158746.3238169.4277781317492.63571104.13968115.7
2.5004.90876.55710.19121290131238.2196857.4229566.9262376.5295186.1327995.6
2.2503.97615.31130.15491594106331159446.5185954.2212562239169.7265677.5
2.0003.14164.19660.1224201784024.5125936.7146942.8167949188955.1209961.2
80T-3M2.0003.14164.19660.1224201784024.5125936.7146942.8167949188955.1209961.2
1.7502.40533.2130.0937263464318.796428.1112532.8128637.5144642.2160746.9
1.5001.76712.36060.0688358447313.870920.782724.194527.5106331118134.4
80T-3H1.2501.22721.63930.047851613289.649214.357416.765619.173821.582023.9
Brake Horsepower Required324856647280